How do I reset the Ghost Controls System when a ZombieLock is missing or removed?

Example Scenarios:

  1. I previously had a Ghost Controls AXZL ZombieLock installed and now I have removed it for some reason or another.  How do I get my Ghost Controls system to work again now that I have removed the AXZL ZombieLock from the installation?
  2. I currently have a Ghost Controls AXZL ZombieLock on my gate but I have disconnected the wires from the control board.  I want to manually keep the ZombieLock open using the key. 

Follow these steps:

  1. If your system is not off already, turn the system control board OFF using the switch on the outside bottom of the system control box.
    On/Off Switch on Control Box
  2. Hold down BOTH the “JOG OPEN” and “JOG CLOSE” for the 1st Arm.
    JOG Buttons for 1st Arm
  3. Turn the system control board ON and continue to hold the JOG OPEN and JOG CLOSE buttons down for approximately 6-8 seconds.
  4. Your system has now reset.
  5. Test your system operation with the Remote Transmitter.